MRI Main Disconnect Panel provides emergency shutdown, overcurrent protection, OSHA Lock Out/Tag Out provision in an OSHPD Pre-approved stand-alone cabinet. The MDP also serves as a local disconnect for the Diagnostic Imaging System. The Main Disconnect Panel allows for an automatic reclosure after a power outage so the system can come back online without maintenance intervention. Available in multiple configurations to meet the needs of any X-Ray suite.
Emergency Power Off function does not trip a circuit breaker, as many alternative designs have the inherent problem of requiring a circuit breaker to be reset. We incorporate a contactor-based NO-TRIP function to remove power from the system when an EPO is pressed. Power will be restored when releasing the EPO. No Circuit Breaker needs to be reset.
Additionally, when MR imaging equipment loses power, a critical challenge is preserving the expensive helium and avoiding the time-consuming task of replacing it. Helium loss results in operational down time as well as exposes the equipment to significant damage. The Bevco Imaging solution supports UPS installations that will help avoid helium quenching. Additionally, True Auto Restart is a feature in the Bevco Engineering Main Disconnect Panel that immediately restores power to the imaging equipment without the need for technical support or facility intervention.
Wide range of voltage and power options to support the smallest magnets to the largest 7T magnets.
Advantages:
- Reduce installation time by providing a single-point power connection
- Proven components and designs eliminate guesswork
- Standard configurations suitable for use in 25ka short-circuit current rated (SCCR) power systems
- Standardized design and testing ensures high product quality and system reliability
- Includes installation and operation manual
- UL and cUL listed, labeled, and tested; conforms to National Electric Code
- Surface or semi-flush mounting
- High SCCR ratings and a variety of custom configurations are available
Please contact Bevco Imaging Suite Controls for consultation - Seismic ICC-ES-AC156 shake tested approval per OSHPD requirements
- Panel disconnect provides OSHA lock-out / tag-out provisions
- Supplied with remote red Emergency OFF guarded Push-to-Latch/Twist-to-Release push button, wall plate and nameplate
- Factory wired and tested. All devices are selected for high reliability and long life
- Door has provisions for padlocking to control access
- Available International CE, 380/400/415V designs include main circuit breaker 30ma, adjustable, RCD protection
Configuration:
Ordering Information:
Basic Panels
Basic Part Number |
3-Phase Voltage |
Main MR Amperage |
Chiller Amperage |
Nominal Dimensions |
||
Height |
Width |
Depth |
||||
MR480-090-BB |
400/415/480 50/60 Hz |
90 |
20 |
24" |
15" |
9" |
System-matched UPS Bypass Panels
Basic Part Number |
kVA Rating |
Amperage |
Nominal Dimensions |
||
Height |
Width |
Depth |
|||
CT480-090-BB |
150 kVA |
90 |
24" |
15" |
9" |
CT480-110-BB |
300 kVA |
110 |
30" |
24" |
9" |
CT480-125-BB |
500 kVA |
125 |
30" |
24" |
9" |
Listed above are common options and configurations. A wide variety of potential combinations of voltage, short-circuit current ratings, and amperage requirements can be accommodated. Please contact us with your specific needs.